1. Lay out the units
The register lists every suite the building has. Two numbers describe it:- in register — the unit rows that exist (what can be spliced and ordered).
- planned — the count on the building record, for the pipeline and coverage.
<floor><nn> — floor 2, unit 3 → 203), what it keeps
and which extra units it would remove. Shrinking is opt-in and never touches
a unit that carries a subscription, a minted location, a splice or a CPE — the
preview names the blocker instead.
Use + Unit for the one-off (a penthouse, a 4B).
A unit’s number is frozen once its location is minted — the number is part of
the identifier printed on labels. Rename before minting.
2. Splice — rear ports
On Documentation, each panel has a wiring sheet: one row per panel port, Rear · unit on the left, Front · switch port on the right, and the state of the pair.- Pick the unit on a rear port to record its splice (one unit per rear port, one rear port per unit).
- Batch splice… fills a range of rear ports with the units that are not spliced yet, in register order (floor, then number). The preview lists every pair before anything is written; the batch is applied all-or-nothing.
- + New unit (sheet header, and inside the rack’s Splice dialog) creates the unit the register is missing and selects it — “unit first” is never a dead end.
3. Patch — front ports
The front side is the movable cord to the switch.- Pick the switch and its port on a front port.
- Batch patch… runs a range of front ports onto the switch’s access ports one to one from a start port (front 1–12 → ethernet1/1–12). Ports already patched are skipped; a switch port already used on the panel is not reused.
4. Mint the location
Back on Units, the Path to service column shows the four steps — spliced › patched › minted › CPE — and a verdict:
Mint now on a row, or Mint n ready units in the toolbar, writes the
location for the effective port: for a NetBox-synced building the canonical
identifier
REGION|SITE|MER|UNIT-nn with the unit location, ONT placeholder and
cable in NetBox; a legacy-named row on the same port is re-minted in place (same
row, new identifier and QR hash). Minting needs the building’s country, province,
city and street on the record — the tab says so when one is missing.
Reading the Occupancy column
Occupancy is derived from the subscriptions, not typed: vacant, install pending or active, with the ISP that serves the line and the subscription reference. The operator never sees a customer name here.- A subscription can be anchored on the unit (install-path orders) or on the port (captive-portal, QR and partner-direct orders). The register reads both, so a live line ordered against the port shows on its suite.
- via port marks a line whose subscription has no unit anchor yet. Assign unit sets it, so a unit delete is refused while the line is live and the dispatch board knows the suite. New port-keyed orders get the anchor automatically when the port serves a unit.
- A CPE bound to the port with no subscription is still vacant: the suite is orderable, the device is simply already there.